RoyalSonic was established with a straightforward goal: to deliver top-notch service at the most affordable prices. Over time, we have evolved our mission to focus on providing outstanding service beyond just email hosting. We understand that our customers have numerous options for email hosting, and we aim to distinguish ourselves from the rest. Our aim is to continually impress our customers with our friendly, prompt, and precise services. We are dedicated to empowering our customers by educating them and enabling them to assist themselves.

DataCenter

No matter which RoyalSonic product you select—be it our high-performance email hosting, cloud servers, or dedicated root servers—you can trust in our advanced and eco-friendly infrastructure. RoyalSonic Online offers you multiple redundant network connections to key Internet exchanges.

Power Supply

  • AC: 230V, 16A    
  • Redundant UPS facilities
  • Battery mode: Approx. 15 minutes
  • Standby power system
  • Diesel power generator for autonomous mode
  • Power is supplied via a raised floor system

Climate Control

  • Energy efficient direct free cooling N+2 redundancy
  • Cold aisle containment
  • Under-floor air conditioning
  • Higher than average raised floor system
  • Monitoring of air temperature and server/distribution cabinets

Fire Protection

• A contemporary early warning fire system encompasses all facilities within the data center park and features an automatic fire alarm system that employs aspirating smoke detectors. • The fire alarm system of the data center is directly linked to the local fire and rescue coordination center, incorporating fault monitoring capabilities. • Fire detectors include alarms. • The division of distinct fire protection zones using fire-resistant doors. • The system automatically closes the doors upon detecting smoke. • Every data center unit is equipped with handheld CO₂ fire extinguishers and portable wheeled CO₂ fire extinguishers. • DC units (buildings) are designed with gaps between them to inhibit the spread of fire (flashover) until the fire department can respond. • Every data center must have designated fire-fighting areas that are to be maintained clear at all times. • Transformers, medium-voltage stations, and battery rooms constructed with fire-resistant walls and fireproof doors. • Cable ducts within firewalls must be sealed for a minimum duration of 90 minutes. • Ventilation ducts within the firewalls are fitted with self-closing fire dampers. • Designated staff members of J.R.D Partner serve as fire protection officers and assistants, maintaining regular communication with local fire departments. • Fire protection strategies tailored for each data center, considering variations in structural design.Variations in local conditions may result in discrepancies among the different data center parks.